Particles measurement is very important in classified area. Different guidelines like ISO, EU GMP has defined certain limits for these particles for a particular class in classified area. Particle counters are used for monitoring of non viable particles. If number of these particles increases in particular area then they may cause product contamination, so control over particles in classified area is very important. But why all guidelines talk about 0.5 and 5.0 micron particles. Why these particles particles are so important to measure and what about the particles smaller than 0.5 micron and particles greater than 5.0 micron, aren't they important?
In classified area non viable particles are generated in the environment through system, process and movement but how viable particles are generated in the classified area? Personnels are the main source of viable particle contamination.Viable particles are carried by the personnels working inside the classified area. Millions of bacteria are shed by the body of personnels on continous basis. But how microbes move in classified area, are they freely movable or require any source for movement? Microbes can't move on its own, first they require a source for attachment and this source is particle. Non viable particles are main source for movement of viable particles because microbes first attach to the non viable particles and after attaching to these particles they are carried from one area to another area through air movement. During non viable particle monitoring 0.5 and 5.0 micron particles are measured because most commonly found bacteria range is in between 0.5 to 5.0 micron so this range of particles are the main source of product contamination and can be carried from one area to another area very easily with the air movement. Size less than 0.5 micron is not very critical because microbes are less likely to attach to this size of particles and greater than 5.0 micron particles become heavy as size of these particles increases and can be easily settled down as compared to 0.5 and 5.0 micron particles. That's why 0.5 and 5.0 micron partilces are measured in pharmaceuticals.
Thanks
Good information sir
ReplyDeleteThanks Vismaysinh Chauhan
DeleteThank you sir, sharing the a valuable information.
Deletedear sir,
ReplyDeletei am confused for this you says non viable particle monitoring 0.5 and 5.0 micron particles are measured because most commonly found bacteria range is in between 0.5 to 5.0 micron,
and i says we are used the HEPA 0.3 micron Pre filter and 5.0 micron post filter. so we found bacteria range is in between 0.5 to 5.0 micron
sorry sir i am just asking..
DeleteDear all,
DeleteAs we know that the smallest size of a particle is 0.2 to which we can see with microscope hence why we should not take 0.2 instead of 0.5.
Sir,
DeleteHVAC is not the source of contamination in the clean room, its human who creates the contamination and other factors thats why...
important & useful informaton. Thanks for sharing.
ReplyDeleteIs this rationale is given in any guideline?
The smallest bacteria is of size 0.3 micron.ok
ReplyDeleteno it is 0.27 brevundimonas diminuta
DeleteYes it is present.
ReplyDeleteWhy 500 bbf if required for toc in water for injection.
ReplyDeleteWhy conductivity of wfi is required nmt than 0.3 microns/cms
ReplyDeleteThanks for ur valuable information
ReplyDeleteVery Nice Information.
ReplyDeletePerfect answer ever read
ReplyDeleteThanku sir for this time of information
ReplyDeleteI have another question about trending both particle size. Should both sizes considered under 1 sample since they are usually collected together or should they be separated to consider 0.5 as 1 sample and 5.0 as 1 also?